Fronius inverter error codes can be confusing when they show up on your system display or in your Solar.web app. Most Fronius codes are informational—the inverter is doing its job protecting your system—but some indicate real problems that need attention. This guide explains the most common Fronius state codes, what they mean, and how to troubleshoot them.
How Fronius state codes are organized
Fronius inverters use a numbering system called “state codes” to communicate status and errors. Unlike simple error messages, these codes are grouped by category, which helps you understand severity at a glance.
| State code | What it means | What to do | |||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 102 | Grid (AC) voltage too high | Reconnects automatically; report it to your utility if it happens daily | |||||||||||||||||||||||||||||||||
| 306 / 307 | Power low / DC voltage low | Normal at dawn and dusk; investigate only if it shows at midday in clear weather | |||||||||||||||||||||||||||||||||
| 401 | Internal communication fault | Restart once; call a technician if it returns | |||||||||||||||||||||||||||||||||
| 407 / 457 | Hardware faults (407: temperature sensor) | Usually needs a technician | |||||||||||||||||||||||||||||||||
| 509 | No feed-in for 24 hours | Check for snow, heavy soiling or a real fault | |||||||||||||||||||||||||||||||||
| 516 |
| Do a full restart; repair or replace if it persists |
1xx codes — Grid issues: The inverter has disconnected because grid voltage or frequency is outside safe limits. State 102 (voltage too high) is the most common in this class. The system will reconnect automatically when the grid stabilizes.
3xx codes — Operational messages: These are informational, not faults. State 306 (power low) and State 307 (DC voltage low) appear at dawn and dusk when there isn’t enough sunlight to generate—completely normal behavior.
4xx codes — Hardware faults: The inverter has detected a component or communication failure. State 401 (no communication with the power stage), State 406/407 (temperature sensor faulty) and State 457 (grid relay sticking) usually need a technician.
5xx codes — Warnings: Alerts that stay on the display until they’re acknowledged. State 509 (no feed-in for 24 hours) can mean snow cover, an open disconnect or a real fault; 502 flags an insulation problem on the panels, 516 means the inverter can’t talk to the battery, and 517 means it’s reducing power because it’s too hot.
Understanding these categories helps you decide whether to wait, reboot, or call your installer.
State 102: AC voltage too high
State 102 is the most common Fronius error code homeowners encounter. It means your inverter measured grid voltage above the limit programmed for your local grid code, and stopped feeding in.
The inverter disconnects to protect itself and your home’s electrical system. It will reconnect automatically when voltage drops, but if this happens repeatedly during peak sun hours, you lose significant generation.
What causes it: The underlying issue is usually grid infrastructure that wasn’t designed for widespread solar export. When multiple homes on your street export power simultaneously during midday, local voltage rises. Homes farthest from the utility transformer see the highest voltage and trip first.
What to do: If you see State 102 occasionally (a few times per month), it’s annoying but not urgent. If it’s happening daily during peak production, contact your utility to report high voltage. In some cases, your installer can adjust the inverter’s volt-watt response settings to reduce tripping without violating grid codes. This is a configuration change, not a repair.
State 102 is a network issue, not an inverter fault. Don’t let anyone sell you a new inverter to “fix” this—it won’t help.
State 306 and 307: DC low and power low
State 306 (power low) and State 307 (DC low voltage) are normal operational messages, not errors. They appear when your solar panels aren’t producing enough voltage or power for the inverter to feed energy to the grid.
You’ll see these codes at sunrise and sunset, on very cloudy days, or if panels are shaded. The inverter needs a minimum threshold of DC input to operate—usually around 150-200 volts depending on the model—and these codes simply mean you’re below that threshold.
When to worry: If State 306 or 307 appears persistently during midday in clear weather, that’s different. It could indicate a problem with your panels, wiring, or DC disconnect. Check for obvious issues like a tripped disconnect switch or heavy soiling on the panels. If everything looks normal and the code persists, contact your installer—it may be a string wiring issue or a failing panel.
For help identifying other system issues, see our guide on outdated solar technology and when components may need attention.
State 401: Communication or grid fault
State 401 on Fronius inverters typically indicates a loss of internal communication between the inverter’s control board and its power stage. On some models, it can also relate to grid monitoring faults.
This is a hardware-level error. It won’t resolve on its own by waiting for better weather or grid conditions.
What to try first: Shut down the inverter using the DC disconnect switch (usually mounted near the inverter or on the side of your house), wait 60 seconds, then restart. This clears the inverter’s memory and re-establishes communication paths. If State 401 clears and doesn’t return, you’re good.
If it persists: Contact your installer or a licensed solar technician. State 401 usually means a failed communication board, loose internal connector, or firmware issue. These aren’t DIY fixes. Fronius has good warranty support, and if your system is under 10 years old and registered on Solar.web, the repair should be covered under warranty.
If your installer is no longer in business, see our article on what to do when your solar installer went out of business.
State 516: No communication with the battery
On current Fronius inverters (Primo, Symo and the hybrid GEN24 models), State 516 means the inverter can’t communicate with the storage unit. On the older IG Plus series, the same number meant one power stage had logged too many errors in a day. Neither is a code that comes from the grid or the weather.
What to check for State 516
Check that the battery is switched on and its communication cable is seated (that’s for your installer if it means opening anything).
What to do: Perform a full shutdown: turn off the DC disconnect, wait two minutes, turn off the AC disconnect (if accessible), wait another minute, then restart in reverse order (AC first, then DC). If State 516 persists after reboot, the inverter likely has a fatal internal error and will need repair or replacement.
Warranty coverage: Fronius’s current U.S. homeowner warranty is a complimentary 10-year Fronius Warranty Plus covering parts, labor and transport, and inverters installed from March 2024 under the earlier program got 10+2 years when registered. Check your registration in Solar.web under “Product registration.” See the warranty section below for details.
Parts availability for Fronius repairs can vary by region and model generation. Older inverters (pre-2018) may have longer lead times for replacement boards. Your installer or service provider can check availability through Fronius support channels.
State 509: No energy fed in for 24 hours
State 509 means the inverter hasn’t fed any energy into the grid in the past 24 hours. It’s a warning, and it stays on the display until it’s acknowledged.
Common causes of State 509
- Snow covering the panels, or a dark, overcast stretch
- A DC or AC disconnect that was switched off (after service, a storm or a power outage)
- A real fault, usually shown by another state code in the Solar.web event log
What to do about State 509
If there’s snow or it’s been dark, wait for a clear day; the warning has no lasting effect. Otherwise check that both disconnects are on and look in Solar.web for other codes around the same time. If the panels are clear, the switches are on and 509 comes back after a sunny day, call your installer or a Fronius service partner.
Using Fronius Solar.web for diagnostics
Every Fronius inverter with built-in data communication automatically sends status updates to the Solar.web monitoring platform. This is one of the most useful diagnostic tools you have as a homeowner—it tracks every state code, when it occurred, and how long it lasted.
How to check your event log: Log in to Solar.web via browser or the Solar.web app. Navigate to your system, then select “System details” or “Event log.” You’ll see a timeline of all state codes. Look for patterns: Does State 102 happen every day at noon? Does State 306 only appear at dawn? Patterns tell you whether the issue is environmental (grid, weather) or hardware (inverter, wiring).
Solar.web also shows real-time and historical production data. If your inverter is online and reporting but production is lower than expected, compare daily output to previous months. A sudden drop without a corresponding state code may indicate panel soiling, shading from new tree growth, or degradation.
Installer access: If you’re working with a service technician, you can grant them temporary access to your Solar.web account. They can pull detailed diagnostic logs remotely, which speeds up troubleshooting and may eliminate a truck roll for simple issues. To grant access, go to “System settings” > “User management” in Solar.web and add their email with installer-level permissions.
For general advice on working with solar service providers, visit our installer directory to find qualified local technicians.
Common Fronius inverter problems
These are the issues that come up most with Fronius systems, and where to start with each.
The inverter keeps tripping at midday (State 102)
Usually high grid voltage on your street, not a broken inverter. Report it to your utility; your installer may be able to adjust settings within grid-code limits.
Solar.web stopped updating
Often the inverter’s Wi-Fi or network connection, not production. Check whether the inverter display shows it producing; if it does, the problem is the data link (router change, new Wi-Fi password, or the inverter’s datamanager). See our Fronius Solar.web guide.
Power drops on hot afternoons (State 517)
The inverter is reducing output to protect itself from heat. Keep the cooling vents clear and make sure it isn’t in full afternoon sun in a closed space.
An insulation warning (State 502)
The inverter found an insulation problem on the panel side, which can be moisture or damaged wiring. If it keeps coming back, have a technician test the array; don’t open DC wiring yourself.
The battery isn’t talking to the inverter (State 516)
Check that the battery is on, then restart the system. If it persists, your installer needs to look at the communication link.
An older IG Plus that keeps faulting
IG Plus inverters are out of production. If one fails out of warranty, compare the repair quote to replacement; see our Fronius inverter replacement cost guide.
When to call for help vs. when to wait
Not every Fronius state code requires immediate action. Here’s a practical decision tree:
Wait and monitor:
- State 102 or 107 (grid voltage/frequency) occurring occasionally—these are grid issues, not inverter faults
- State 306 or 307 (low DC/power) at dawn, dusk, or on cloudy days—completely normal
- State 509 (no feed-in for 24 hours) after a known weather event or if you’ve been away and snow/leaves have accumulated
Try a reboot first:
- State 401 or other 4xx codes—communication and hardware faults often clear with a power cycle
- Any code that appeared suddenly after a storm or power outage
Call your installer immediately:
- State 516 (battery communication) or 457 (grid relay) that persists after a restart
- Any state code accompanied by visible damage (burn marks, melted components, sparking)
- Repeated daily trips during peak sun with significant lost production
- Codes you don’t recognize in the 4xx or 5xx range that won’t clear
If you’re unsure, check the Solar.web event log and take a screenshot. Send it to your installer with a description of when the issue started. Most experienced techs can triage remotely and tell you whether it’s urgent.
If you’re considering upgrading your system or adding battery storage to improve resilience, see our comparison guide on Tesla vs SolarEdge batteries.
Fronius warranty and parts availability
Fronius is known for responsive warranty support, but outcomes depend on your inverter’s age, registration status, and regional parts inventory.
Current warranty terms: Fronius USA offers homeowners a complimentary 10-year Fronius Warranty Plus, and an optional 5-year extension (to 15 years) that has to be bought within the first 6 months. Registering on Solar.web, which Fronius asks for within 30 months of delivery, starts the warranty from your installation date. Inverters installed from March 1, 2024 under the earlier program got 10+2 years when registered, with yearly extensions available up to 20 years.
What’s covered: The Fronius Warranty Plus covers parts, labor and transport. Some older registrations carry the base Fronius Warranty, which covers parts only; your certificate in Solar.web shows which you have. If you’re making a warranty claim, Fronius works directly with your installer to ship replacement parts or, in some cases, a replacement inverter. You won’t pay out of pocket for the part itself, but you may be responsible for labor if you only have the base warranty.
Parts availability: Fronius maintains good parts inventory for current-generation inverters (Primo, Symo, GEN24, Tauro). Older models—particularly the IG Plus series and early Galvo inverters—may face longer lead times or, in rare cases, substitution with remanufactured units. If your inverter is out of production and out of warranty, replacement may be the only option. Consult with a qualified installer about compatibility if you’re replacing an older Fronius unit.
For warranty claims, your installer typically initiates the process through Fronius Solar.SOS, the company’s online service tool. You can also contact Fronius support directly if your installer is unavailable, but having your system registered on Solar.web significantly speeds up the process.
More Fronius guides: Fronius inverter replacement cost and how to use Fronius Solar.web.
Frequently Asked Questions
Final Thoughts
Fronius inverter error codes are designed to protect your system, not frustrate you. Most state codes are informational—the inverter doing exactly what it’s supposed to do in response to grid conditions or low sunlight. The key is knowing which codes are normal, which ones clear with a reboot, and which ones require professional help.
Use your Solar.web account actively. The event log is the best diagnostic tool you have, and it’s free. Patterns matter more than individual codes. A State 102 once a month is a nuisance; a State 102 every day at noon is a grid problem worth reporting to your utility. A State 401 that clears after reboot is a glitch; one that persists is a service call.
EnergyScout exists to help you get the most out of your solar investment. If you’re dealing with persistent errors and your original installer isn’t responsive, use our installer directory to find a qualified service provider in your area. And if you’re considering solar for the first time, understanding how inverters communicate issues—and how manufacturers like Fronius support their products over the long term—should be part of your decision process.