If your SMA inverter is showing an error code on its display or in the Sunny Portal, you’re likely dealing with one of dozens of event numbers that indicate specific grid, DC, or internal faults. Many SMA inverters were installed 10–15 years ago, and finding clear support information can be frustrating. This guide walks you through the most common SMA inverter error codes, what they mean, and when you can troubleshoot yourself versus when to call a technician.

How SMA inverter error codes work

SMA inverters display error codes as numbered “events” on the inverter’s LCD screen or in the Sunny Portal monitoring platform. Most SMA models show a 3- or 4-digit event number, while some older models (like the SB3-5000TL-20 and early STP8-17000TL-10 units) only display a 1- or 2-digit code on the screen. For these older units, you can retrieve the full event number through the Sunny Explorer software.

Quick reference for the most common events:

EventWhat it meansClears on its own?What to do
101 / 102 / 103 / 301Grid undervoltage, overvoltage, frequency, or 10-minute average voltage out of rangeUsuallyReport recurring events to your utility
3501 / 3701Insulation fault / residual current faultNoCall a qualified technician
3403 / 3404DC voltage too high (operating / at startup)Sometimes, on cold morningsHave an installer check the array configuration if it persists
6406DC overcurrentNoDisconnect DC and call a technician
6501Internal overtemperatureUsuallyCheck ventilation and shade around the inverter
6443 / 6447
EventWhat it meansClears on its own?What to do
101 / 102 / 103Grid voltage or grid impedance too highUsuallyReport recurring events to your utility
202 / 203 / 205Grid disconnected, AC cable damaged or grid voltage too lowUsually, when the grid returnsIf the grid is up, have the AC side checked
30110-minute average grid voltage out of rangeUsuallyReport recurring events to your utility
3401 / 3402DC overvoltage at the inputNo — disconnect the DC sideCall a technician; this can damage the inverter
3501Insulation failure (ground fault in the array)NoCall a qualified technician
3601 / 3701Leakage or residual current too highSometimesCall a technician if it repeats
3801 / 3802DC overcurrentUsually, briefly interrupts feed-inCall a technician if it repeats
3901 / 3902Waiting for DC start conditionsYesNormal at dawn, dusk and in low light
6001–6438Internal self-diagnosis faultNoContact SMA Service
6501 / 8001 / 8003Overtemperature or temperature deratingUsuallyCheck ventilation and shade around the inverter
NoRepair or replace, under warranty if covered

Event numbers fall into rough groups: grid faults (100s–300s), PV array and DC-side issues (3000s), internal device errors (6000s) and temperature derating (8000s). Exact numbers and meanings vary by model, so check the event list in your inverter’s manual on the SMA website. Understanding which category your error falls into helps you quickly identify whether it’s a temporary grid issue, a physical system problem, or a hardware failure.

If you’re not sure where to find your event number, check the inverter display first. If the screen is blank or unresponsive, log into the Sunny Portal or use the Sunny Explorer app to check the inverter status remotely. Many errors clear on their own once grid or weather conditions return to normal, but safety faults like insulation failures keep the inverter offline until the cause is fixed.

Grid faults (Event 101, 102, 103, 202, 301)

Grid monitoring faults are the most common SMA inverter error codes, especially in areas with high solar penetration or unstable utility grids. Events 101, 102 and 103 mean the grid voltage or grid impedance at your inverter’s connection point is too high, so the inverter disconnected. Event 301 means the 10-minute average grid voltage is out of range, and 202–205 point to the grid being down, a damaged AC cable or grid voltage that’s too low.

These faults occur when the inverter detects unsafe grid conditions and disconnects to comply with safety standards. In many cases, the inverter will automatically reconnect once grid voltage or frequency returns to normal. If you see these codes occasionally—especially during midday when solar production is high—it’s typically a grid-side issue, not a problem with your system.

However, if grid monitoring faults appear daily or persist for hours, contact your utility company to report voltage issues. Chronic overvoltage can indicate your local grid is oversaturated with solar exports, and the utility may need to adjust voltage regulation equipment. You can also check your inverter’s grid settings in Sunny Portal to confirm they match your region’s requirements, but do not adjust these without consulting a qualified installer or SMA support.

Ground and insulation faults (Event 3501, 3601, 3701)

Event 3501: Insulation failure

Event 3501 means the inverter has detected a ground fault in the PV array. Events 3601 (leakage current too high) and 3701 (residual current too high) are related warnings.

These codes indicate the inverter has detected a ground fault or excessively low insulation resistance between your solar array and ground. Insulation faults can be caused by damaged cables, moisture intrusion in junction boxes, or panel defects that create a pathway for current to leak to ground.

Unlike grid faults, insulation errors will not auto-clear. The inverter will remain offline until the fault is physically repaired. If the code stays after a repair, the technician may need to clear it from the inverter’s interface.

To diagnose an insulation fault, a qualified technician will use a megohmmeter to test insulation resistance on each string. The test measures resistance between the positive and negative conductors, and separately from each conductor to ground. Resistance should typically exceed 1 megohm. If a string shows low resistance or a dead short to ground, the technician will isolate that string and inspect connectors, junction boxes, and panel bypass diodes for damage. Do not attempt to troubleshoot insulation faults yourself—these involve high DC voltage and require specialized test equipment.

If your original installer is no longer in business, use our directory to find a local solar service technician experienced with SMA equipment.

DC-side errors (Event 3401, 3402, 3801, 3802, 3901)

Event 3401 and 3402: DC overvoltage

These mean the voltage coming from the panels is above what the inverter’s input can take, which SMA warns can destroy the inverter. Disconnect the DC side if you can do so safely and call a technician.

Event 3801 and 3802: DC overcurrent

Too much current at the DC input; the inverter briefly stops feeding in. If it repeats, have a technician check the array wiring.

Event 3901 and 3902: Waiting for DC start conditions

Not a fault. The panels aren’t yet producing enough to start feeding in, which is normal at dawn, dusk and in low light.

High DC voltage errors are often caused by system design mismatches, such as too many panels wired in series for the inverter’s input range, or cold weather conditions that temporarily boost panel voltage above the inverter’s maximum. Cold, clear mornings raise panel voltage, so an overvoltage event that shows up only then still points to an array design problem worth having checked. However, if the error persists or occurs frequently, your array configuration may exceed the inverter’s specifications and will require reconfiguration by a licensed installer.

DC overcurrent faults (Event 3801/3802) are less common and can indicate a wiring error or a short in the array. These errors require immediate inspection. Disconnect the DC input at the inverter and do not reconnect until a technician has verified the array wiring and tested for shorts. Ignoring DC overcurrent faults can damage the inverter and create a fire risk.

Self-consumption and battery mode issues

If your SMA inverter is paired with a battery storage system (such as the Sunny Boy Storage or Sunny Island series), you may encounter errors related to self-consumption mode, battery communication, or energy-saving mode. These faults are less common on standard grid-tied systems but can be confusing for homeowners with older hybrid setups.

Battery communication errors often appear when the inverter cannot detect the battery or when the battery management system (BMS) reports a fault. Check that all CAN bus or Modbus communication cables are securely connected, and verify that the battery firmware is up to date. SMA’s energy-saving mode can also trigger status messages if the battery enters deep discharge protection or if there’s insufficient PV power to charge the battery during the day.

Self-consumption configuration errors are usually related to incorrect settings in the Sunny Portal or inverter parameters. If your system is not switching between grid export, battery charging, and load coverage as expected, review the operating mode settings in the inverter’s web interface or Sunny Portal. For complex battery issues, consult the system integrator who installed the storage—battery troubleshooting often requires both inverter and battery manufacturer support.

Using Sunny Portal to diagnose SMA inverter errors

The Sunny Portal is SMA’s online monitoring platform, and it’s one of the best tools for diagnosing persistent inverter issues without a site visit. If your inverter is connected to the internet via Ethernet or Wi-Fi, it will upload event logs, performance data, and diagnostic information to Sunny Portal automatically.

To check error codes in Sunny Portal, log in to your account and navigate to the plant monitoring page. Under the inverter status section, you’ll see the most recent event number and message. Click “Detailed Analysis” to view historical event logs, voltage and current trends, and production comparisons across multiple days. This is especially useful for identifying patterns—such as grid faults that occur only at midday, or insulation errors that appeared after a rainstorm.

Sunny Portal also offers communication monitoring, which alerts you if the inverter stops sending data. If your inverter goes offline in Sunny Portal but the system is still producing power, the issue is likely a lost Wi-Fi or Ethernet connection, not an inverter fault. Check that your router has assigned a valid IP address to the inverter and that DHCP is enabled. Firmware updates can also be pushed remotely through Sunny Portal on newer models, which can resolve some recurring event codes.

Keep in mind that older SMA inverters may have limited Sunny Portal functionality or require a separate communication accessory (like the Sunny WebBox) to connect. If you’re struggling to access monitoring data on a system installed before 2015, the inverter may not support modern cloud connectivity.

Internal faults and overheating (Event 6001–6438, 6501, 8003)

Event codes in the 6400-series and higher typically indicate internal hardware failures, such as sensor errors, failed self-tests, or component overheating. Event 6501 (internal overtemperature) is one of the most common and can be caused by inadequate ventilation, direct sunlight exposure, or an internal component fault. Events in the 6000–6438 range are internal self-diagnosis faults; SMA’s manual says to contact SMA Service, and they often mean repair or replacement.

If your inverter shows an overtemperature fault, first check its installation location. SMA inverters should be mounted in a shaded, well-ventilated area with clearance on all sides. If the inverter is installed in direct sun or inside a hot garage, it may be thermally shutting down to protect itself. Cleaning dust and debris from the cooling vents can also help, but if the inverter continues to overheat in normal conditions, an internal component may have failed.

For fatal hardware errors—especially on inverters that are 10+ years old—replacement is often the most cost-effective option. SMA no longer manufactures many older Sunny Boy and Sunny Tripower models, but the company will provide a compatible replacement unit under warranty or extended warranty coverage. If your inverter is out of warranty, you’ll need to purchase a new unit. Fortunately, modern SMA inverters are backward-compatible with older array configurations in most cases.

Check your inverter’s warranty status in the SMA Online Service Center. Warranty terms depend on model and install date. SMA America lists a standard 10-year factory warranty on current Sunny Boy Smart Energy inverters, extendable up to 25 years, and asks owners to register in its Online Service Center. Older units may have shorter terms, so check your serial number there.

When to call SMA support versus a local technician

Knowing when to call SMA directly versus hiring a local solar service technician can save you time and money. For warranty claims, firmware issues, or questions about event code meanings, contact SMA’s service line or open a ticket in the SMA Online Service Center. SMA support can remotely diagnose many issues, push firmware updates, and authorize warranty replacements that ship within 48 hours.

For physical repairs—such as insulation faults, wiring issues, or array problems—you’ll need a licensed electrician or solar installer to visit your site. SMA does not dispatch technicians for on-site service, so you’ll need to find a qualified local installer who can troubleshoot and repair the system. Many installers are familiar with SMA equipment even if they didn’t install your original system, especially for common models like the Sunny Boy and Sunny Tripower series.

If your original installer is no longer in business—a common issue for systems installed in the early 2010s—don’t panic. SMA inverters are widely supported, and any competent solar service provider can diagnose and repair most faults. Bring your event code number and any screenshots from Sunny Portal when you contact a technician, as this will help them prepare the right tools and parts for the service call.

More SMA guides: SMA inverter replacement cost, how to use SMA Sunny Portal and SolarEdge vs. SMA for a replacement.

Frequently Asked Questions

+What does event 3501 mean on my SMA inverter?
Event 3501 indicates an insulation fault, meaning the inverter has detected excessively low insulation resistance between your solar array and ground. This is a safety-critical error that prevents the inverter from operating until the fault is repaired. A technician will need to test the array wiring and panels with a megohmmeter to locate and fix the ground fault.
+Why does my SMA inverter show grid fault errors every day?
Daily grid fault errors (like Event 102 or Event 301) usually indicate your local utility grid voltage is exceeding the inverter's safe operating range, especially during peak solar production hours. This is common in neighborhoods with high solar adoption. Contact your utility to report chronic overvoltage—they may need to adjust voltage regulation equipment.
+Can I reset an SMA inverter error code myself?
Some error codes will auto-clear once the underlying condition resolves, such as grid faults that disappear when utility voltage normalizes. However, safety-critical faults like insulation errors (Event 3501) require physical repair before the inverter will restart. You can attempt a manual reboot by turning off the DC and AC disconnects, waiting 30 seconds, and reconnecting, but if the fault persists, call a technician.
+Where can I find my SMA inverter event code if the display is blank?
If your inverter display is blank or unresponsive, log into the Sunny Portal or use the Sunny Explorer software to check the inverter status remotely. The event code will be listed under the device status or event log section. If you don't have online monitoring set up, you'll need to check the inverter in person or have a technician retrieve the code directly from the unit.
+Is my SMA inverter still covered under warranty?
It depends on the model and when it was installed. SMA America lists a 10-year standard factory warranty on current Sunny Boy Smart Energy inverters, extendable up to 25 years; older units may have shorter terms. Check your warranty status in the SMA Online Service Center using your inverter's serial number. If your inverter is out of warranty and needs replacement, you can purchase a new unit or explore extended warranty options for future coverage.

Final Thoughts

SMA inverters are known for their reliability and longevity, but like any piece of equipment, they can encounter faults over time—especially as systems age past the 10-year mark. The good news is that SMA’s event code system is detailed and well-documented, making it easier to identify the root cause of an issue compared to many other inverter brands.

If you’re dealing with a recurring error code, don’t ignore it. Many faults—especially grid monitoring issues and insulation errors—are early warnings of problems that can worsen if left unaddressed. Use the Sunny Portal to track trends, and reach out to SMA support or a local technician for help diagnosing and repairing the issue. Even if your original installer is no longer around, qualified solar service providers can work on SMA equipment and help keep your system running smoothly.